Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.
Automated cardiovascular magnetic resonance image analysis with fully convolutional networks
767
Zitationen
23
Autoren
2018
Jahr
Abstract
BACKGROUND: Cardiovascular resonance (CMR) imaging is a standard imaging modality for assessing cardiovascular diseases (CVDs), the leading cause of death globally. CMR enables accurate quantification of the cardiac chamber volume, ejection fraction and myocardial mass, providing information for diagnosis and monitoring of CVDs. However, for years, clinicians have been relying on manual approaches for CMR image analysis, which is time consuming and prone to subjective errors. It is a major clinical challenge to automatically derive quantitative and clinically relevant information from CMR images. METHODS: Deep neural networks have shown a great potential in image pattern recognition and segmentation for a variety of tasks. Here we demonstrate an automated analysis method for CMR images, which is based on a fully convolutional network (FCN). The network is trained and evaluated on a large-scale dataset from the UK Biobank, consisting of 4,875 subjects with 93,500 pixelwise annotated images. The performance of the method has been evaluated using a number of technical metrics, including the Dice metric, mean contour distance and Hausdorff distance, as well as clinically relevant measures, including left ventricle (LV) end-diastolic volume (LVEDV) and end-systolic volume (LVESV), LV mass (LVM); right ventricle (RV) end-diastolic volume (RVEDV) and end-systolic volume (RVESV). RESULTS: By combining FCN with a large-scale annotated dataset, the proposed automated method achieves a high performance in segmenting the LV and RV on short-axis CMR images and the left atrium (LA) and right atrium (RA) on long-axis CMR images. On a short-axis image test set of 600 subjects, it achieves an average Dice metric of 0.94 for the LV cavity, 0.88 for the LV myocardium and 0.90 for the RV cavity. The mean absolute difference between automated measurement and manual measurement is 6.1 mL for LVEDV, 5.3 mL for LVESV, 6.9 gram for LVM, 8.5 mL for RVEDV and 7.2 mL for RVESV. On long-axis image test sets, the average Dice metric is 0.93 for the LA cavity (2-chamber view), 0.95 for the LA cavity (4-chamber view) and 0.96 for the RA cavity (4-chamber view). The performance is comparable to human inter-observer variability. CONCLUSIONS: We show that an automated method achieves a performance on par with human experts in analysing CMR images and deriving clinically relevant measures.
Ähnliche Arbeiten
Recommendations for Cardiac Chamber Quantification by Echocardiography in Adults: An Update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging
2015 · 17.898 Zit.
Recommendations for Chamber Quantification: A Report from the American Society of Echocardiography’s Guidelines and Standards Committee and the Chamber Quantification Writing Group, Developed in Conjunction with the European Association of Echocardiography, a Branch of the European Society of Cardiology
2005 · 11.322 Zit.
2017 ESC Guidelines for the management of acute myocardial infarction in patients presenting with ST-segment elevation
2017 · 9.706 Zit.
ACC/AHA Guidelines for the Management of Patients With ST-Elevation Myocardial Infarction—Executive Summary
2004 · 8.372 Zit.
2015 ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation
2015 · 8.306 Zit.
Autoren
- Wenjia Bai
- Matthew Sinclair
- Giacomo Tarroni
- Ozan Oktay
- Martin Rajchl
- Ghislain Vaillant
- Aaron M. Lee
- Nay Aung
- Elena Lukaschuk
- Mihir M. Sanghvi
- Filip Zemrak
- Kenneth Fung
- José Miguel Paiva
- Valentina Carapella
- Young Jin Kim
- Hideaki Suzuki
- Bernhard Kainz
- Paul M. Matthews
- Steffen E. Petersen
- Stefan K. Piechnik
- Stefan Neubauer
- Ben Glocker
- Daniel Rueckert