Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.
Comparison of Automated Versus Vacuum-Assisted Biopsy Methods for Sonographically Guided Core Biopsy of the Breast
138
Zitationen
3
Autoren
2003
Jahr
Abstract
OBJECTIVE: The purpose of this study was to compare the outcome of sonographically guided core biopsies performed with the 14-gauge automated gun with the outcome of those performed with the 11-gauge vacuum-assisted device. Outcome was defined in terms of missed tumors, the need (both immediate and delayed) for a second biopsy, histologic underestimation, and complication rates. MATERIALS AND METHODS: We retrospectively reviewed all sonographically guided core biopsies performed between January 1997 and August 2001. Before February 2000, biopsies were performed using the 14-gauge automated gun and after that time, with either the 14-gauge automated gun or the 11-gauge vacuum-assisted device. During the study period, 181 biopsies were performed with the 14-gauge automated gun and 100 with the 11-gauge vacuum-assisted device. RESULTS: The histologic results of the core biopsies were similar for the group who underwent biopsy with the 14-gauge automated gun and the group who underwent biopsy with the 11-gauge vacuum-assisted device: malignant, 19% versus 19%; benign, 78% versus 79%; and high-risk lesion or other, 3% versus 2%, respectively (p > 0.7). Complications were rare and similar for both methods: 2% for the 14-gauge automated gun and 3% for the 11-gauge vacuum-assisted device (p = 0.46). A second biopsy was recommended immediately after the first in 14% of the patients who underwent biopsy with the 14-gauge automated gun versus 17% of those who underwent biopsy with the 11-gauge vacuum-assisted device (p = 0.47). Recommendation for delayed rebiopsy due to interval change occurred in 2.5% of the patients who underwent biopsy with the 14-gauge automated gun method and 3% of those who underwent biopsy with the 11-gauge vacuum-assisted device (p = 0.94). CONCLUSION: No significant differences were found in the outcomes of sonographically guided core biopsies performed with the automated gun compared with those performed with the vacuum-assisted device in terms of missed cancers, underestimation, complications, or the need (immediate or delayed) for a second biopsy.
Ähnliche Arbeiten
Evaluation of Factors Related to Late Recurrence - Later than 10 Years after the Initial Treatment - in Primary Breast Cancer
2013 · 13.213 Zit.
Effects of chemotherapy and hormonal therapy for early breast cancer on recurrence and 15-year survival: an overview of the randomised trials
2005 · 7.603 Zit.
A Gene-Expression Signature as a Predictor of Survival in Breast Cancer
2002 · 6.512 Zit.
A Multigene Assay to Predict Recurrence of Tamoxifen-Treated, Node-Negative Breast Cancer
2004 · 6.333 Zit.
Twenty-Year Follow-up of a Randomized Trial Comparing Total Mastectomy, Lumpectomy, and Lumpectomy plus Irradiation for the Treatment of Invasive Breast Cancer
2002 · 6.185 Zit.