Clinical comparison of high-resolution with high-sensitivity collimators in low-count cardiac gated blood pool studies.
0
Zitationen
3
Autoren
1988
Jahr
Abstract
We compared high-sensitivity (HS) and high-resolution (HR) collimators for 2.5-minute low-count acquisitions in 13 patients undergoing cardiac gated blood pool studies. High-count acquisitions served as standards. Ejection fractions calculated from low-count acquisitions were plotted against high-count acquisitions for each collimator; the variance of the HS plot was lower, and HS images were superior.