Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.
A Novel Deep Learning Based Computer-Aided Diagnosis System Improves the Accuracy and Efficiency of Radiologists in Reading Biparametric Magnetic Resonance Images of the Prostate
110
Zitationen
16
Autoren
2021
Jahr
Abstract
OBJECTIVE: The aim of this study was to evaluate the effect of a deep learning based computer-aided diagnosis (DL-CAD) system on radiologists' interpretation accuracy and efficiency in reading biparametric prostate magnetic resonance imaging scans. MATERIALS AND METHODS: We selected 100 consecutive prostate magnetic resonance imaging cases from a publicly available data set (PROSTATEx Challenge) with and without histopathologically confirmed prostate cancer. Seven board-certified radiologists were tasked to read each case twice in 2 reading blocks (with and without the assistance of a DL-CAD), with a separation between the 2 reading sessions of at least 2 weeks. Reading tasks were to localize and classify lesions according to Prostate Imaging Reporting and Data System (PI-RADS) v2.0 and to assign a radiologist's level of suspicion score (scale from 1-5 in 0.5 increments; 1, benign; 5, malignant). Ground truth was established by consensus readings of 3 experienced radiologists. The detection performance (receiver operating characteristic curves), variability (Fleiss κ), and average reading time without DL-CAD assistance were evaluated. RESULTS: The average accuracy of radiologists in terms of area under the curve in detecting clinically significant cases (PI-RADS ≥4) was 0.84 (95% confidence interval [CI], 0.79-0.89), whereas the same using DL-CAD was 0.88 (95% CI, 0.83-0.94) with an improvement of 4.4% (95% CI, 1.1%-7.7%; P = 0.010). Interreader concordance (in terms of Fleiss κ) increased from 0.22 to 0.36 (P = 0.003). Accuracy of radiologists in detecting cases with PI-RADS ≥3 was improved by 2.9% (P = 0.10). The median reading time in the unaided/aided scenario was reduced by 21% from 103 to 81 seconds (P < 0.001). CONCLUSIONS: Using a DL-CAD system increased the diagnostic accuracy in detecting highly suspicious prostate lesions and reduced both the interreader variability and the reading time.
Ähnliche Arbeiten
Docetaxel plus Prednisone or Mitoxantrone plus Prednisone for Advanced Prostate Cancer
2004 · 5.712 Zit.
Sipuleucel-T Immunotherapy for Castration-Resistant Prostate Cancer
2010 · 5.471 Zit.
Decision Curve Analysis: A Novel Method for Evaluating Prediction Models
2006 · 5.251 Zit.
Increased Survival with Enzalutamide in Prostate Cancer after Chemotherapy
2012 · 4.559 Zit.
Biochemical Outcome After Radical Prostatectomy, External Beam Radiation Therapy, or Interstitial Radiation Therapy for Clinically Localized Prostate Cancer
1998 · 4.504 Zit.
Autoren
Institutionen
- University Hospital of Basel(CH)
- NYU Langone Health(US)
- Siemens Healthcare (United States)(US)
- Siemens (Switzerland)(CH)
- Lightpoint Medical (United Kingdom)(GB)
- Screen(US)
- Radboud University Medical Center(NL)
- Radboud University Nijmegen(NL)
- Geriatrische Gesundheitszentren(AT)
- Catholic University of Korea(KR)
- Changhai Hospital(CN)
- Second Military Medical University(CN)
- Charité - Universitätsmedizin Berlin(DE)
- Berlin Institute of Health at Charité - Universitätsmedizin Berlin(DE)