Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.
Intraoperative Applications of Artificial Intelligence in Robotic Surgery: A Scoping Review of Current Development Stages and Levels of Autonomy
45
Zitationen
10
Autoren
2022
Jahr
Abstract
OBJECTIVE: A scoping review of the literature was conducted to identify intraoperative artificial intelligence (AI) applications for robotic surgery under development and categorize them by (1) purpose of the applications, (2) level of autonomy, (3) stage of development, and (4) type of measured outcome. BACKGROUND: In robotic surgery, AI-based applications have the potential to disrupt a field so far based on a master-slave paradigm. However, there is no available overview about this technology's current stage of development and level of autonomy. METHODS: MEDLINE and EMBASE were searched between January 1, 2010 and May 21, 2022. Abstract screening, full-text review, and data extraction were performed independently by 2 reviewers. The level of autonomy was defined according to the Yang and colleagues' classification and stage of development according to the Idea, Development, Evaluation, Assessment, and Long-term follow-up framework. RESULTS: One hundred twenty-nine studies were included in the review. Ninety-seven studies (75%) described applications providing Robot Assistance (autonomy level 1), 30 studies (23%) application enabling Task Autonomy (autonomy level 2), and 2 studies (2%) application achieving Conditional autonomy (autonomy level 3). All studies were at Idea, Development, Evaluation, Assessment, and Long-term follow-up stage 0 and no clinical investigations on humans were found. One hundred sixteen (90%) conducted in silico or ex vivo experiments on inorganic material, 9 (7%) ex vivo experiments on organic material, and 4 (3%) performed in vivo experiments in porcine models. CONCLUSIONS: Clinical evaluation of intraoperative AI applications for robotic surgery is still in its infancy and most applications have a low level of autonomy. With increasing levels of autonomy, the evaluation focus seems to shift from AI-specific metrics to process outcomes, although common standards are needed to allow comparison between systems.
Ähnliche Arbeiten
The SCARE 2020 Guideline: Updating Consensus Surgical CAse REport (SCARE) Guidelines
2020 · 5.581 Zit.
The SCARE 2023 guideline: updating consensus Surgical CAse REport (SCARE) guidelines
2023 · 3.004 Zit.
Virtual Reality Training Improves Operating Room Performance
2002 · 2.810 Zit.
Objective structured assessment of technical skill (OSATS) for surgical residents
1997 · 2.263 Zit.
Does Simulation-Based Medical Education With Deliberate Practice Yield Better Results Than Traditional Clinical Education? A Meta-Analytic Comparative Review of the Evidence
2011 · 1.752 Zit.