OpenAlex · Aktualisierung stündlich · Letzte Aktualisierung: 24.04.2026, 10:54

Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.

Diving Into AutoML in Medical Imaging: Solution for Non-ML Practitioners

2024·7 Zitationen·IEEE AccessOpen Access
Volltext beim Verlag öffnen

7

Zitationen

4

Autoren

2024

Jahr

Abstract

Within the healthcare sector, deploying Machine Learning (ML) models involves trial-and-error approaches, considerable time to create task-specific models, and collaboration between ML experts and physicians. To overcome these hurdles, Automated Machine Learning (AutoML) appears as a promising resource towards the advancement of precision and personalised medicine. Despite being a hot topic, AutoML remains relatively underexplored in the realm of medical imaging. To address this gap, the research objectives are to enrich the body of knowledge by comprehensively exploring the AutoML solutions, evaluating and comparing their performance, and even verifying their compliance to Explainable Artificial Intelligence (XAI) principles. Furthermore, we provide a unified solution with open-source AutoML solutions, as they seek to democratize access for less experienced users. Thus, this research paper contains a methodology to identify and evaluate 5 solutions, Fastai, Ktrain, Ludwig, Autogluon, and Autokeras, across 3 relevant medical imaging datasets. Their evaluation involved binary classifications using chest X-rays and breast histopathological images, and a multi-class scenario with brain Magnetic Resonance Imaging (MRI) images. Results reveal that both Ktrain and Fastai consistently demonstrate lower F1-Score values, regardless of the dataset. This stems from their limited level of automation, as the user is required to introduce the type of architecture and fine-tune certain hyperparameters. In contrast, Ludwig when employing the <monospace xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">EfficientNet</monospace> architecture, it roughly takes 10 minutes to achieve an F1-Score of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$98.06{\pm }0.86$ </tex-math></inline-formula>% with the chest X-ray dataset. About 17 minutes to acquire <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$98.16{\pm }0.50$ </tex-math></inline-formula>% with the histopathological dataset, and nearly 7 minutes to reach an F1-Score of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$96.52{\pm }1.07$ </tex-math></inline-formula>% with the brain MRI dataset. In this dataset is where Autokeras and Autogluon failed to provide suitable metrics for a typical multi-class problem. Nonetheless, in both binary scenarios, they achieve state-of-art results. Although having a higher execution time than Ludwig, they have a more robust search space. Finally, our findings highlight the need to incorporate XAI principles to improve the user’s experience, particularly for non-ML practitioners.

Ähnliche Arbeiten

Autoren

Institutionen

Themen

Radiomics and Machine Learning in Medical ImagingAI in cancer detectionArtificial Intelligence in Healthcare and Education
Volltext beim Verlag öffnen