Impact of a computed tomography-based artificial intelligence software on radiologists’ workflow for detecting acute intracranial hemorrhage
1
Zitationen
7
Autoren
2025
Jahr
Abstract
Impact of a computed tomography-based artificial intelligence software on radiologists' workflow for detecting acute intracranial hemorrhage PURPOSETo assess the impact of a commercially available computed tomography (CT)-based artificial intel-ligence (AI) software for detecting acute intracranial hemorrhage (AIH) on radiologists' diagnostic performance and workflow in a real-world clinical setting. METHODSThis retrospective study included a total of 956 non-contrast brain CT scans obtained over a 70-day period, interpreted independently by 2 board-certified general radiologists.Of these, 541 scans were interpreted during the initial 35 days before the implementation of AI software, and the re-maining 415 scans were interpreted during the subsequent 35 days, with reference to AIH probabil-ity scores generated by the software.To assess the software's impact on radiologists' performance in detecting AIH, performance before and after implementation was compared.Additionally, to evaluate the software's effect on radiologists' workflow, Kendall's Tau was used to assess the correla-tion between the daily chronological order of CT scans and the radiologists' reading order before and after implementation.The early diagnosis rate for AIH (defined as the proportion of AIH cases read within the first quartile by radiologists) and the median reading order of AIH cases were also compared before and after implementation. RESULTSA total of 956 initial CT scans from 956 patients [mean age: 63.14 18.41 years; male patients: 447 (47%)] were included.There were no significant differences in accuracy [from 0.99 (95% con-fidence interval: 0.99-1.00) to 0.99 (0.98-1.00),P = 0.343], sensitivity [from 1.00 (0.99-1.00) to 1.00 (0.99-1.00),P = 0.859], or specificity [from 1.00 (0.99-1.00) to 0.99 (0.97-1.00),P = 0.252] following the implementation of the AI software.However, the daily correlation between the chronological order of CT scans and the radiologists' reading order significantly decreased [Kendall's Tau, from 0.61 (0.48-0.73) to 0.01 (0.00-0.26),P < 0.001].Additionally, the early diagnosis rate significantly increased [from 0.49 (0.34-0.63) to 0.76 (0.60-0.93),P = 0.013], and the daily median reading order of AIH cases significantly decreased [from 7.25 (Q1-Q3: 3-10.75) to 1.5 (1-3), P < 0.001] after the implementation. CONCLUSIONAfter the implementation of CT-based AI software for detecting AIH, the radiologists' daily reading order was considerably reprioritized to allow more rapid interpretation of AIH cases without com-promising diagnostic performance in a real-world clinical setting. CLINICAL SIGNIFICANCEWith the increasing number of CT scans and the growing burden on radiologists, optimizing the workflow for diagnosing AIH through CT-based AI software integration may enhance the prompt and efficient treatment of patients with AIH.
Ähnliche Arbeiten
Dabigatran versus Warfarin in Patients with Atrial Fibrillation
2009 · 11.162 Zit.
Rivaroxaban versus Warfarin in Nonvalvular Atrial Fibrillation
2011 · 9.361 Zit.
Apixaban versus Warfarin in Patients with Atrial Fibrillation
2011 · 8.870 Zit.
Global, regional, and national burden of stroke and its risk factors, 1990–2019: a systematic analysis for the Global Burden of Disease Study 2019
2021 · 7.404 Zit.
Thrombolysis with Alteplase 3 to 4.5 Hours after Acute Ischemic Stroke
2008 · 6.607 Zit.